Deutsch English
back

SwaroLine cable IHP 2 x 6 mm² single insulated

 
     
Art.No. 8159 IHP_6E   SwaroLine cable IHP single insulated
Conductor properties:   copper blank 6 mm², Kl. 6
diameter: 3.3 mm
Sheath properties:   XLPE, insulation thickness ca. 1.6 mm,
black, halogen free according to IEC 60754-1, flexible
oil- and grease resistant, no corrosive fire gases according to
IEC 60754-2, lean of smoke according to IEC 61034
Dimensions twin cable:   13.8 x 6.8 mm (+/- 0,2 mm)
Weight:   159 kg/km
Operating temperature continual:   -25° C up to +90° C
Operating temperature temporary:   qualified for bitumen casting
installation below max. 2 cm of melted asphalt
Nominal voltage:   450 V / 750 V, 50 Hz
Test voltage:   3.5 kV / 50 Hz, 5 minutes
Copper standard:   ICE 60228 / CENELEC HD 383
Labeling:   with dimensions
Delivery:   in pieces of 200 m with ready made compensors
or as end piece of 100 m


request for product information